Air Conditioning in Sydney
49/3 Hornsey street, Rozelle, NSW, 2039, Australia

$3,289.00

Set B36AWY-GMD LG Slim Mid static duct – Inverter. Indoor B36AWYNGMD – Outdoor B36AWYUGMD / 10.0kW Cooling – 11.2kW Heating Capacity with wired wall controller PQRCVSL0QW

Description

Indoor B36AWYNGMD
Capacity Cooling Min/Rated/Max kW 4.0 / 10.0 / 11.0
Heating Min/Rated/Max kW 4.5 / 11.2 / 12.3
Power Input Cooling Rated kW 3.24
Heating Rated kW 3.36
Power Supply V/?/Hz 220-240 / 1 / 50
EER 3.09
COP 3.33
Piping Connection Liquid mm ? 9.52
Gas mm ? 15.88
Drain O.D./I.D. mm ? 32 / 25
Air Flow Rate High/Medium/Low m3/min 32.0 / 28.0 / 24.0
l/s 533 / 466 / 400
Sound Pressure Cooling High/Medium/Low dBA 36 / 34 / 33
Heating High/Medium/Low dBA 36 / 34 / 33
Sound Power Cooling Max dBA 60
Dehumidification Rate l/h 3.2
Dimensions Body WxHxD mm 1,250 X 270 X 700
Net Weight Body kg 36.0 (79.4)
Supply Air Spigot WxH mm 1206 x 200
Return Air Spigot WxH mm 1205 x 231
Fan Motor Output W 295 x 1
External Static Pressure (-pre set) Min~Max Pa 25 – (58.8 factory) – 147
Outdoor B36AWYUGMD
Compressor Type Twin Rotary
Airflow Rate Rated m3/min 45 x 2
l/s 750 x 2
Sound Pressure Cooling Rated dBA 53
Heating Rated dBA 54
Sound Power Cooling Max dBA 66
Dimensions WxHxD mm 950 X 1,170 X 330
Net Weight kg 81
Refrigerant Type R410A
Charge g 2,800
Additional Charge (after 7.5m) g/m 40
Operation Range (Outdoor) Cooling Min~Max ?C DB (-)15 ~ 48
Heating Min~Max ?C WB (-)18 ~ 18
Power Supply V/?/Hz 220~240 / 1 / 50
Running Current Cooling/Heating Rated A 14.1/14.6
Power Supply Cable N x mm2 3C x 5.0
Transmission Cable N x mm2 4C x 0.75
Circuit Breaker A 40
Piping Length Total Max m 50
Piping Elevation Difference IDU-ODU Max m 30
Piping Connection Liquid mm ? 9.52
Gas mm ?15.88

Additional information

Weight 207 kg